CORTEXA
← Browse
arxiveess.IVcs.CV2026-07-14

Exact and Calibrated Diffusion Reconstruction for Digital Breast Tomosynthesis

Imade Bouftini

Limited-angle digital breast tomosynthesis (DBT) reconstructs a volume from a few low-dose projections over a narrow arc. At a representative nine-view, $25^{\circ}$ protocol more than 98% of image space is unmeasured, so a learned prior must supply structure in the missing wedge. Conditional diffusion priors achieve strong perceptual quality here but leave three clinical obstacles: inexact data consistency, unlocalized hallucination, and uncalibrated uncertainty. We enforce measurements exactly by replacing the per-step proximal update of a conditional diffusion sampler with exact Euclidean projection onto the data-consistent set, computed via an $m$-dimensional dual system with a one-time Gram matrix $AA^{\top}$ factorization. This projection costs 4.5 ms per step (a $248\times$ speedup) and drives the data residual to the double-precision floor ($2.4\times10^{-13}$). We prove it is the $ρ\to0$ limit of the proximal step, provide a no-harm theorem, and show that exactly consistent sample ensembles have variance supported on null($A$). Thus, the mean's entire error lies in the unmeasured subspace covered by the uncertainty map. On patient-derived breast phantoms, this improves fidelity at no depth-resolution cost. Conversely, a proximal step applied post-update degrades quality, isolating the consistency step's placement as decisive. Isotonic recalibration brings the ensemble spread to a calibrated error scale (expected calibration error $0.029\to0.008$; standardized error $4.7\to0.96$), ranking errors better than the pure prior. We also repair a 20.3% adjoint mismatch in a deployed projector via a materialized operator of record. This is the first data-consistent, uncertainty-calibrated learned reconstruction for limited-angle DBT. The solver naturally relaxes to discrepancy-ball and maximum-a-posteriori modes for noisy measurements.

View free PDFSource page

Related papers

arxiveess.IVcs.CVcs.LG2026-07-03

Piecewise Dynamic Diffusion Regularization for Reconstruction of Cardiac Cine MRI

Florian Fürnrohr, Reinhard Heckel

Real-time cardiac cine MRI enables visualization of the beating heart during free breathing, but severe undersampling and motion make reconstruction highly challenging. A central challenge for reconstruction is incorporating powerful priors of cardiac anatomy while remaining comp…

View free PDFSource page
arxiveess.IVcs.CV2026-06-26

Measured-Subspace Consistency: A Plug-and-Play Operator for Diffusion Posterior Sampling in Accelerated MRI Reconstruction

Junhyeok Lee, Kyu Sung Choi

Diffusion posterior samplers for accelerated MRI can reconstruct accurately yet still disagree on the acquired k-space across samples, placing posterior variability on coefficients the scanner has already measured. We identify this measured-subspace leakage as a physical-admissib…

View free PDFSource page
arxiveess.IVcs.CVcs.LGmath.NAphysics.comp-ph2026-07-12

Projection-Domain Sensitivity Analysis of Vertebral DRRs Under Intrinsic Calibration Perturbation

Lin Li, Chaochao Zhou, Benjamin Aubert, Junlin Guo, Junchao Zhu

Accurate geometric calibration is essential for fluoroscopy-guided spinal imaging, digitally reconstructed radiograph (DRR) generation, and 2D--3D vertebral registration. Although calibration quality is typically evaluated using reconstruction-based metrics such as reprojection e…

View free PDFSource page
arxiveess.IVcs.CV2026-06-26

Anatomy-Grounded Synthetic Coronary Angiography for Geometry-Informed Multi-View Matching

In Kyu Lee, Sumin Seo, Jaesik Min

Accurate correspondence matching across multiple angiographic views is the prerequisite for 3D coronary reconstruction and interventional guidance. However, the development of robust deep learning models for this task has been stifled by a fundamental data bottleneck. Obtaining g…

View free PDFSource page
arxivcs.CVcs.AIeess.IV2026-07-24

Time-Reversed Imaging: A Multimodal Benchmark and Framework for Reconstructing Past Human-Environment Interactions

Jorge Bacca, Kebin Contreras, Luis Toscano-Palomino, Mauro Dalla Mura

We introduce time-reversed imaging, a new paradigm that infers what just happened in a scene from fading multimodal traces. Instead of extrapolating or interpolating video frames, our goal is to infer past human-environment interactions from residual physical imprints observable…

View free PDFSource page
arxiveess.IVcs.CVphysics.optics2026-07-24

The Lift Spectrum: How Measurement-to-Space Adaptivity Shapes Robustness in Image-Free Single-Pixel Sensing

Yuyuan Han, Jingwei Li, Long Qiu, Chong Wang, Wenxuan Hao, Jiangyu Han, et al.

Single-pixel sensing encodes a scene as a short sequence of coded measurements, and image-free methods infer the task directly from that sequence. Removing reconstruction does not remove the difficulty: it relocates it to the lift, the map from 1D measurements to a 2D representat…

View free PDFSource page