CORTEXA
← Browse
arxivphysics.med-phcs.AIcs.CVeess.IVeess.SP2026-07-03

Harmonic-Aware Transformer for Real-Time Catheter Localization in Interventional Procedures of Magnetic Particle Imaging

Abuobaida M. Khair, Wenjing Jiang, Xiaoli Yang, Moritz Wildgruber, Xiaopeng Ma

Magnetic particle imaging (MPI) enables real-time, radiation-free tracking of magnetic nanoparticle-coated instruments, making it highly suitable for interventional procedures. This study proposes a harmonic-aware transformer framework that directly predicts catheter tip positions from raw MPI voltage signals, eliminating the need for image reconstruction and reducing computational latency. The framework incorporates frequency-domain preprocessing to isolate the 2nd to 8th drive-field harmonics, enhancing the signal-to-noise ratio while preserving motion-relevant features. A transformer architecture with six encoder layers and eight attention heads is employed to learn spatio-temporal dependencies across the three receive axes (x, y, z) for accurate three-dimensional position estimation. The model is trained on simulated MPI signals and evaluated on real in vitro datasets under standard, bending, and heartbeat-like motion conditions. The proposed method achieves sub-millimeter localization accuracy, with a minimum L2 error of 0.103 +/- 0.092 mm and mean absolute errors (MAEs) of 0.039 +/- 0.046 mm, 0.054 +/- 0.049 mm, and 0.060 +/- 0.044 mm along the (x, y, z) axes, respectively, for the bending dataset. Across all datasets, the MAE ranges from 0.165 mm to 0.655 mm, demonstrating consistent performance. The optimized inference achieves a latency of 0.55 ms per frame and a throughput of approximately 1800 frames per second, confirming real-time capability. Compared with conventional MPI-guided approaches relying on image reconstruction, the proposed framework provides improved accuracy, reduced latency, and enhanced robustness under complex motion conditions. These results highlight the potential of harmonic-aware transformer models as efficient and scalable solutions for real-time catheter localization in interventional MPI.

View free PDFSource page

Related papers

arxivcs.CVcs.AIeess.IV2026-07-24

Time-Reversed Imaging: A Multimodal Benchmark and Framework for Reconstructing Past Human-Environment Interactions

Jorge Bacca, Kebin Contreras, Luis Toscano-Palomino, Mauro Dalla Mura

We introduce time-reversed imaging, a new paradigm that infers what just happened in a scene from fading multimodal traces. Instead of extrapolating or interpolating video frames, our goal is to infer past human-environment interactions from residual physical imprints observable…

View free PDFSource page
arxivcs.CRcs.CVcs.SEeess.IV2026-07-31

A Biometric Sensor Network to Enable Real-Time Measurement of Individual Student Engagement in STEM Lecture Environments

Ahmed Elsayed

Student engagement (SE) is a critical predictor of academic performance and retention in STEM education, yet existing measurement approaches are often intrusive, manually intensive, or unsuitable for real-time classroom use. This thesis proposes a novel $\textit{Biometric Sensor…

View free PDFSource page
arxivcs.CVcs.AI2026-07-23

When Are Reasoning-Based Guardrails Not Efficient? ResponseGuard: A Fast Vision-Language Guard for Real-Time Moderation

Dongbin Na

A vision-language AI assistant returns its answer as a stream of generated tokens. Therefore, a safety guard that watches that answer has to keep up with the stream and stop a harmful reply before a user reads it. Recent vision-language guardrails instead generate a chain of thou…

View free PDFSource page
arxivcs.CVcs.AI2026-07-31

DualDiT: A Conditional Dual-Output Diffusion Transformer for Joint OCT Image and Segmentation Mask Generation

Fernando García-Torres, Rocío del Amor, Sandra Morales, Álvaro Barroso, Peter Heiduschka, Björn Kemper, et al.

Background and Objective: Generating realistic medical images with anatomically accurate segmentation masks helps address the shortage of annotated data in medical imaging, particularly in optical coherence tomography (OCT) of mouse eyes, where manual retinal layer delineation is…

View free PDFSource page
arxivcs.CVcs.AI2026-07-31

Dense Temporal Contrast Synthesis via Conditioned Latent Transport

Smriti Joshi, Apostolia Tsirikoglou, Daniel M. Lang, Richard Osuala, Noah Márquez Varaa, Alejandro Guzman, et al.

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is essential for breast cancer management, but reliance on gadolinium-based contrast agents (GBCAs) restricts use in contraindicated populations, prolongs scan protocols, and presents environmental toxicity concerns.…

View free PDFSource page
arxivcs.CVcs.AIcs.CR2026-07-24

ISPCloak: Weaponizing ISP for Optimization-Free Physical Camouflage against Deepfake Detectors

Jiale Zhao, Jiajun Wan, Lei Tang, Ye Qin, Kebing Jin, Jinghui Qin

The rapid advancement of generative models has spurred the critical need to evaluate the worst-case robustness of deepfake detectors. In this paper, we reveal a fundamental blind spot in current forensic paradigms: while existing detectors excel at capturing digital synthesis art…

View free PDFSource page