CORTEXA
← Browse
arxivcs.CVcs.AI2026-07-21

Deep Learning Estimation of Sex, Age, Height, and Weight from CT-derived Digitally Reconstructed Radiographs

Tomohiro Kikuchi, Kohei Yamamoto, Yukihiro Nomura, Yosuke Yamagishi, Takeharu Yoshikawa, Toshiaki Akashi, Jun Kamohara, Hiroyuki Fujii, Harushi Mori

Purpose: To develop and validate a deep learning ensemble for estimating adult sex, age, height, and weight from coronal digitally reconstructed radiographs (DRRs) generated from diagnostic CT. Materials and Methods: This retrospective study included 128,621 CT examinations from 80,004 adults at nine institutions in Japan. Three multitask models-ConvNeXt-Base, ViT-Base/16, and MaxViT-Base-were fine-tuned using coronal DRRs and combined by weighted averaging. Data were split by institution into training (114,147 examinations; seven institutions), tuning (4,305; one institution), and test (10,169; one institution) sets; generalizability was assessed on two non-Japanese datasets. Accuracy and mean absolute error (MAE) were used to evaluate sex classification and age, height, and weight regression, respectively. Body surface area (BSA)-corrected heart and liver volume trends were compared using true versus estimated height and weight. Results: In the test set (median age, 69.9 years; 4,899 of 10,169 [48.2%] male), overall sex-classification accuracy was 0.997 (95% CI, 0.996-0.998), and MAEs were 3.57 years (3.51-3.63), 2.59 cm (2.54-2.64), and 3.40 kg (3.34-3.47) for age, height, and weight, respectively. In examinations covering the chest through pelvis, accuracy was 1.000, and MAEs were 3.15 years, 2.28 cm, and 3.18 kg, respectively. BSA calculated from estimated values reproduced age-related heart and liver volume trends obtained using true values. On non-Japanese datasets, height error increased but was reduced by continued fine-tuning. Conclusion: The ensemble estimated adult sex, age, height, and weight from CT-derived DRRs, with generally lower errors in examinations with broader anatomical coverage.

View free PDFSource page

Related papers

arxivcs.CVcs.AIcs.LG2026-07-24

CARDIAG: A Dense Segment Classification Benchmark of Deep Learning Architectures for Coronary Angiography

Dominik Bernard Lau, Hubert Malinowski, Jerzy Szyjut, Adam Brzeski, Tomasz Dziubich, Radosław Targoński, et al.

Accurate pixel-level classification of coronary angiograms is critical for cardiovascular disease assessment, yet the field lacks standardized evaluation protocols. In this work we demonstrate a new benchmark for the assessment of deep learning models which densely classify pixel…

View free PDFSource page
arxivcs.CVcs.AIcs.RO2026-07-24

SM4RT: Learning Structured Motion Geometry for 4D Reconstruction

Shing Ho J. Lin, Wenzhao Zheng, Dong Zhuo, Yuqi Wu, Jie Zhou, Jiwen Lu

Geometry Foundation Models (GFMs) have substantially advanced monocular 3D reconstruction, yet extending this capability to 4D dynamic understanding remains a fundamental challenge. Most existing motion perception methods (e.g., sparse tracking, dense point-wise flow) treat motio…

View free PDFSource page
arxivcs.CVcs.AI2026-07-31

OsteoCAD: A Human-in-the-Loop Cloud-Edge Framework for Bone Tumor Segmentation

Maximo Rodriguez-Herrero, Dante D. Sanchez-Gallegos, Heriberto Aguirre-Meneses, Marco Antonio Núñez-Gaona, J. L. Gonzalez-Compean, Jesus Carretero

Artificial Intelligence (AI) and Deep Learning (DL) have notably advanced medical image analysis, yet many health- care organizations struggle to adopt them due to limited com- putational resources and specialized expertise. To address these barriers, we introduce OsteoCAD, a mod…

View free PDFSource page
arxivcs.LGcs.AIcs.CV2026-07-31

A Human-Centered Validation of the Explainability-Performance Coefficient

Christian Oliva, Luis F. Lago-Fernández

The rapid adoption of deep learning models in high-risk domains has intensified the need for trustworthy Explainable Artificial Intelligence (XAI). However, objectively evaluating explanation fidelity and aligning XAI metrics with human-centered understanding remain critical open…

View free PDFSource page
arxivcs.CVcs.AIcs.LG2026-07-31

TAVI-TEC: An AI-Based Tool for Procedural Planning of Transcatheter Aortic Valve Implantation

Alessandra Zerillo, Stefano Cannata, Diego Bellavia, Daniele Ciriello, Simone Manini, Salvatore Pasta, et al.

Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is b…

View free PDFSource page
arxivcs.CVcs.AI2026-07-23

SCALE: Self-Supervised Constraint-Aware Layout GEneration for Local P&R DRV Fixing at Advanced Nodes

Chia-Tung Ho, Haoyu Yang, Guanglei Zhou, Yoshi Nishi, Yaguang Li, Walker Turner, et al.

As semiconductor manufacturing advances toward sub-2nm nodes, local place-and-route (P&R) design-rule violation (DRV) fixing is increasingly limited by complex rule interactions, dense multi-layer routing geometries, and foundry-specific constraints. While Large Language Models (…

View free PDFSource page