CORTEXA
← Browse
arxivcs.CV2026-07-22

Development of an automated, reliable, and clinically meaningful artificial intelligence (AI) tool for diagnosing cardiac disease from conventional cardiovascular magnetic resonance (CMR) images

Sina Amirrajab, Volker Vehof, Michael Bietenbeck, Nuriye Akyol, Redouane Bouras, Khuraman Isgandarova, Alexandru Zlibut, Philipp Stalling, Ali Yilmaz

Aims: Cardiovascular magnetic resonance (CMR) imaging enables non-invasive assessment of myocardial structure, function, and pathology, but requires substantial experience in interpretation of CMR images that could be supported by artificial intelligence (AI)-based models. However, use of AI models for enhanced CMR reading is limited by labor-intensive data curation, suboptimal model performance, and unclear implementation pathways. Methods and results: We developed an automated data curation pipeline for CMR-based cardiovascular disease (CVD) diagnosis, integrating open-source locally-run large language models (LLMs) to extract diagnostic labels from narrative CMR reports and preprocessing multimodal imaging data, including cine and late-gadolinium-enhancement (LGE) CMR sequences. Three vision foundation models (DINO, VST, UMedPT) were fine-tuned across these modalities in a two-stage approach. The dataset comprised hypertrophic cardiomyopathy (HCM), dilated cardiomyopathy (DCM), ischemic cardiomyopathy (ICM), cardiac amyloidosis (CA), and normal controls (NOR). A total of 988 curated cases were randomly divided into 742 for training and 246 for validation. Fine-tuned AI-models achieved high discriminative diagnostic performance on an independent test set comprising 1067 patients , with individual AUC-ROC values of up to 0.937 for the correct diagnosis of HCM and 0.945 for cardiac amyloidosis. Ensemble strategies combining multiple models and modalities further improved AI-based diagnostic accuracy and robustness, achieving the highest overall diagnostic performance for HCM (AUC=0.959, CI [0.936-0.978]), CA (AUC=0.966, CI [0.939-0.986]), NOR (AUC=0.872, CI [0.852-0.894]), DCM (AUC=0.848, CI [0.808-0.885]) and ICM (AUC=0.840, CI [0.809-0.868]). All training and inference code, along with the trained model weights, are publicly available on https://github.com/sinaamirrajab/CMR_CVD.

View free PDFSource page

Related papers

arxivcs.LGcs.AIcs.CV2026-07-23

M$^3$-Gen: Interpretable Multimodal Generation of Gene Expression Profiles Using Clinical and Imaging Data

Francesca Pia Panaccione, Carlo Sgaravatti, Marco Venere

Integrating heterogeneous biomedical data, including clinical metadata, histopathology images, and molecular profiles, is crucial for comprehensive disease understanding. However, gene expression data acquisition remains constrained by high costs and privacy concerns, limiting it…

View free PDFSource page
arxivcs.CV2026-07-31

Progressive Decision-Making for Localizing Open-Ended AI-Generated Image Forgeries

Jingyi Hou, Xiaoxia Chen, Leyu Zhou, Zhichuang Wang, Zhijie Liu

AI-generated image forgeries are becoming increasingly realistic and difficult to characterize with fixed manipulation patterns. As generative models continue to evolve, it is impractical to expect a localization model to exhaustively learn all possible forgery appearances from l…

View free PDFSource page
arxivcs.LGcs.CV2026-07-23

Counterfactual Explainability Framework With CycleGAN And Counterfactual-Classifier Alignnment Score for Retinal Disease Classification

Kritanu Chattopadhyay, Sayanjit Singha Roy, Soumya Chatterjee

Automated detection of vision impairing retina-based ocular conditions from fundus images is important for early screening, timely referral and reducing dependency on specialist-only assessment, for which neural network-based deep learning (DL) models have been widely utilized. H…

View free PDFSource page
arxivcs.CVcs.AIcs.LG2026-07-31

TAVI-TEC: An AI-Based Tool for Procedural Planning of Transcatheter Aortic Valve Implantation

Alessandra Zerillo, Stefano Cannata, Diego Bellavia, Daniele Ciriello, Simone Manini, Salvatore Pasta, et al.

Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is b…

View free PDFSource page
arxivcs.CV2026-07-22

SIINR: Structurally Informed Implicit Neural Representations for super-resolution with uncertainty quantification of clinical quality diffusion MRI datasets

Tom Hendriks, William Consagra, Anna Vilanova, Yogesh Rathi, Maxime Chamberland

Diffusion Magnetic Resonance Imaging (dMRI) is a powerful tool for probing brain microstructure, but clinical acquisitions are often limited by low out-of-plane resolution, resulting in degraded structural information and reduced utility for advanced analysis. We introduce SIINR…

View free PDFSource page
arxivcs.CV2026-07-24

RadSight: Towards Perceptually Reliable Multimodal Radiology Image Understanding

Jianqin Liu, Weiwei Cao, Wanxing Chang, Ruifeng Yuan, Bowen Shi, Zhilin Zheng, et al.

Medical multimodal large language models (MLLMs) are increasingly expected to perform complex image understanding tasks, yet their reliability is often compromised by frequent errors in visual interpretation. To systematically trace these failures, we traverse the hierarchy from…

View free PDFSource page